Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 11(5): e0154000, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27166955

RESUMO

BACKGROUND: HIV infection is a concern in the army troupes because of the risk behaviour of the military population. In order to allow regular access to CD4+ T cell enumeration of military personnel as well as their dependents and civilians living with HIV, the Senegalese Army AIDS program is implementing PIMATM Alere technology in urban and semi-urban military medical centres. Validation such device is therefore required prior their wide implementation. The purpose of this study was to compare CD4+ T cell count measurements between the PIMATM Alere to the BD FACSCountTM. METHODOLOGY: We selected a total of 200 subjects including 50 patients with CD4+ T-cells below 200/mm3, 50 between 200 and 350/mm3, 50 between 351 and 500/mm3, and 50 above 500/mm3. CD4+ T-cell count was performed on venous blood using the BD FASCountTM as reference method and the PIMATM Point of Care technology. The mean biases and limits of agreement between the PIMATM Alere and BD FACSCountTM were assessed with the Bland-Altman analysis, the linear regression performed using the Passing-Bablok regression analysis, and the percent similarity calculated using the Scott method. RESULTS: Our data have shown a mean difference of 22.3 cells/mm3 [95%CI:9.1-35.5] between the BD FACSCountTM and PIMATM Alere CD4 measurements. However, the mean differences of the two methods was not significantly different to zero when CD4+ T-cell count was below 350/mm3 (P = 0.76). The Passing-Bablok regression in categorized CD4 counts has also showed concordance correlation coefficient of 0.89 for CD4+ T cell counts below 350/mm3 whilst it was 0.5 when CD4 was above 350/mm3. CONCLUSION: Overall, our data have shown that for low CD4 counts, the results from the PIMATM Alere provided accurate CD4+ T cell counts with a good agreement compared to the FACSCountTM.


Assuntos
Contagem de Linfócito CD4/instrumentação , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Militares , Monitorização Imunológica/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Adulto , Idoso , Contagem de Linfócito CD4/métodos , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/virologia , Feminino , Citometria de Fluxo , Infecções por HIV/prevenção & controle , Infecções por HIV/virologia , Hospitais Militares/organização & administração , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/métodos , Sistemas Automatizados de Assistência Junto ao Leito/organização & administração , Assunção de Riscos , Comportamento Sexual/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...